Q-MASTER /  Q-MASTER PLUS  /  
Q-Switched Nd:YAG Laser  /  Q-Switched & Long Pulsed Nd:YAG Laser (2 in 1)

  • Q-MASTER

– Six Wavelength available
Standard: 532nm, 1064nm
Optional: 585nm, 595nm, 650nm, 660nm

– Adjustable Spot Size 2-10mm

– Highly effective against pigmentation

– Safe, no side effects & faster treatment

– Flat-Top-Mode Applied (New concept of BMO method by optimizing beam mode)

Laser for Skin Care
  • Q-MASTER PLUS

– Six Wavelength available
Standard: 532nm, 1064nm
Optional: 585nm, 595nm, 650nm, 660nm

– Adjustable Spot Size 2-10mm & 11-15mm
(Two Hand pieces)

– Highly effective for treating pigmentation and hair removal
(One Device can treat for both of skin care and hair removal)

– Safe, no side effects & faster treatment

– Flat-Top-Mode Applied
(New concept of BMO method by optimizing beam mode)

Laser for Skin Care

Applications

⦁Tattoo Removal ⦁Toning ⦁Fine Wrinkle ⦁Nevus of Ota ⦁Abnom
⦁Eye Line ⦁Blue Nevus ⦁Eye Brow ⦁Speckled Nevus
(Big Size)
⦁Lentigo
⦁Cafe Au Lait Spot ⦁Seborrheic Keratosis ⦁Hyper pigmentation ⦁Speckled Nevus
(Small Size)
⦁Freckle
⦁Melasma ⦁Fine Hair Breaching ⦁Nail Fungus ⦁Hair Removal
(Q-MASTER PLUS only)
⦁Vascular
(Q-MASTER PLUS only)

Technology

Q-MASTER & Q-MASTER PLUS irradiates laser of single wavelength – 1064nm or 532nm – toward the skin for a very short time (nano second level) and transforms optical energy into thermal energy. Using the selective photothermolysis and heat resolving principle, it protects the normal skin but destroys and treats the pigment lesions. In addition, it absorbs tattoo ink by resolving the target pigment into fine particles.

Laser for Skin Care

What is the Selective Photothermolysis?

A principle under which the normal skin can be  protected while the pigment areas are absorbed and destroyed by the laser selectively.

Absorption Spectrum for Melanin and Hemoglobin

As shown in the figures right, the laser of 1064nm penetrates deep into the skin, while the laser of 532nm and 1064nm absorbs red oxyhemoglobin and reddish brown melanin respectively.

Laser for Skin Care

Top Hat Mode

Top Hat Mode Beam provides that evenly energy can be evenly irradiated at targeted skin area.
It makes proper treatment and can minimize skin damage.

Laser for Skin Care

Single and Double Pulse (PTP)

Q-MASTER & Q-MASTER PLUS offer energy delivery in both Single Pulse and Double Pulse (PTP) modes.
PTP technology disperses the laser energy into two consecutive pulses, mitigating peak power while delivering maximum energy of up to 1.8J per pulse. By creating a Top Hat beam, maximum energy may be delivered evenly over the skin without risking epidermal injury. Both single pulse and double pulse are available in both the Q-Switched 1064nm and Q-Switched 532nm wavelengths.

Laser for Skin Care

Various Hand-pieces

Fractional Hand-piece

The fractional hand-piece uses fractional beams (360 spots, 16x16mm) to allow
higher fluence (J/cm2) compared to the bulk mode hand-piece, allowing it to
effectively destroy various pigmentations which were hard to treat before.

Specification

  • Q-MASTER
Laser Type Nd:YAG Laser
Wavelength Standard: 532, 1064nm

Optional: 585, 595, 650, 660nm

Pulse Duration 532 / 1064 5-6ns
1064 Genesis 330us
Output Power 532 50-500mJ
1064 Single 100-1000mJ
1064 PTP 100-1800mJ
1064 Genesis 100-2300mJ
585 / 595 50-250mJ
650 / 660 50-150mJ
Spot Size 2-10mm(532, 1064)

2mm(585, 650)

3mm(595, 660)

Frequency 1-10Hz
Power Supply 220-240V~, 50/60Hz
Cooling System Circulated Water Cooling
Dimensions 410(W) x 950(D) x 1000(H)mm
Weight 95kgs
Display 10.2“ Touch Screen Color LCD
Optional Hand-piece 585, 595, 650, 660 DYE Hand-piece

532&1064 Fractional Hand-piece

  • Q-MASTER PLUS
Laser Type Nd:YAG Laser
Wavelength Standard: 532, 1064nm

Optional: 585, 595, 650, 660nm

Pulse Duration 532 / 1064 5-6ns
1064 Genesis 330us
1064 Long 5-30ms
Output Power 532 50-500mJ
1064 Single 100-1000mJ
1064 PTP 100-1800mJ
1064 Genesis 100-4500mJ
1064 Long 1-50J
585 / 595 50-250mJ
650 / 660 50-150mJ
Spot Size 2-15mm(532, 1064)

2mm(585, 650)

3mm(595, 660)

Frequency 1-10Hz(Normal)

1Hz(Long)

Power Supply 220-240V~, 50/60Hz